Hydraulic cartridge valves
SAROIT TPS-08, TPS-10 and TPS2-10 are spool-type cartridge sequence valves that open a specified flow path when control pressure reaches a preset setting. Compare the port operation, spring range, cavity and operating pressure to select a valve for your hydraulic circuit.
For complete model-specific specifications, drawings and performance curves, see the TPS-08 cartridge sequence valve page.
Compare the sequence valve models
| Model | Catalog operating pressure | Cavity | Controlled flow path | Pilot and drain |
|---|---|---|---|---|
| TPS-08 | 240 bar | 08-3 | 1 → 2 | Internal pilot and drain |
| TPS-10 | 240 bar | 10-3 | 1 → 2 | Internal pilot and drain |
| TPS2-10 | 207 bar | 10-3 | 3 → 2, controlled by pressure at port 1 | Port 1 pilot; internal spring-chamber drain at port 2 |
TPS-08 and TPS-10 allow flow from port 2 to port 3 in their steady state. TPS2-10 blocks port 3 to port 2 until the control pressure reaches its setting. For TPS2-10, back pressure at port 2 affects the setting directly at a 1:1 ratio.
Operating pressure and spring setting are separate specifications. A spring range is the available adjustment range; it does not define the complete valve or manifold pressure rating.
Model data, symbols and drawings
Public reference listing: 8 November 2026. The catalog edition and controlled drawing revision are not identified in this page's reference listing. This is a website reference date, not an engineering revision. Before selection or ordering, confirm the exact valve model, spring option and controlled drawing revision.
TPS-08 sequence valve

Port 1 blocked; flow from port 2 to port 3 permitted. Preset pressure at port 1 opens flow from port 1 to port 2.
| Specification | Catalog value |
|---|---|
| Operating pressure | 240 bar |
| Cavity | 08-3 |
| Temperature range | -40 to +120 °C |
| Internal leakage | 82 cc/min maximum; catalog condition: up to 85% of nominal setting |
| Cartridge thread | 3/4-16 UNF |
| Drawing dimensions | 119 mm overall; 40.6 mm lower section; 25.4 mm hex across flats |



Technical reference: SAROIT product catalog. Confirm the selected model, operating conditions and current drawing before ordering.
TPS-10 sequence valve

Port 1 blocked; flow from port 2 to port 3 permitted. Preset pressure at port 1 opens flow from port 1 to port 2.
| Specification | Catalog value |
|---|---|
| Operating pressure | 240 bar |
| Cavity | 10-3 |
| Temperature range | -40 to +120 °C |
| Internal leakage | 82 cc/min maximum; catalog condition: up to 85% of nominal setting |
| Cartridge thread | 7/8-14 UNF |
| Drawing dimensions | 122 mm overall; 46.1 mm lower section; 25.4 mm hex across flats |



Technical reference: SAROIT product catalog. Confirm the selected model, operating conditions and current drawing before ordering.
TPS2-10 sequence valve

Flow from port 3 to port 2 blocked. Preset pressure at port 1 opens flow from port 3 to port 2.
Back-pressure condition: Port 2 back pressure adds to the setting at a 1:1 ratio.
| Specification | Catalog value |
|---|---|
| Operating pressure | 207 bar |
| Cavity | 10-3 |
| Temperature range | -40 to +120 °C |
| Internal leakage | 82 cc/min maximum; catalog condition: up to 85% of nominal setting |
| Cartridge thread | 7/8-14 UNF |
| Drawing dimensions | 125 mm overall; 46 mm lower section; 25.4 mm hex across flats |



Technical reference: SAROIT product catalog. Confirm the selected model, operating conditions and current drawing before ordering.
Spring ranges and catalog presets
| Model | Spring code | Adjustment range | Preset |
|---|---|---|---|
| TPS-08 | 3 | 3.4-20.7 bar | 10 bar |
| TPS-08 | 6 | 6.9-41.4 bar | 21 bar |
| TPS-08 | 13 | 10.3-89.7 bar | 45 bar |
| TPS-08 | 24 | 31.0-165.5 bar | 83 bar |
| TPS-10 | 4 | 2.8-28 bar | 13.8 bar |
| TPS-10 | 21 | 14.5-145 bar | 72.5 bar |
| TPS2-10 | 4 | 5.5-27.6 bar | 13.8 bar |
| TPS2-10 | 8 | 13.8-55.2 bar | 27.6 bar |
| TPS2-10 | 15 | 20.7-103 bar | 51.5 bar |
| TPS2-10 | 21 | 28-145 bar | 72.5 bar |
Specify a setting within the selected spring range. A blank setting field means the catalog preset. The catalog example 0120 means a setting of 120 bar.
Ordering information and body options
Provide the model and size, spring code, pressure setting in bar and body port code. State whether you require the cartridge only or a valve fitted to a housing.
| Model | Cartridge only | SAE body port codes | BSP body port codes |
|---|---|---|---|
| TPS-08 | Blank body code | 4T = SAE 4; 6T = SAE 6 | 2G = G1/4; 3G = G3/8 |
| TPS-10 | Blank body code | 6T = SAE 6; 8T = SAE 8 | 2G = G1/4; 3G = G3/8 |
| TPS2-10 | Blank body code | 6T = SAE 6; 8T = SAE 8 | 2G = G1/4; 3G = G3/8 |
The catalog lists other porting as available. Include the requested thread and connection standard in your enquiry for confirmation.
Check the complete circuit and assembly
- Match the cavity, cartridge thread, port numbering and hydraulic function to the manifold drawing.
- Specify the required flow, setting pressure, downstream back pressure, fluid and temperature.
- Choose the body material for the complete operating conditions. Catalog body limits are 207 bar for 6061-T6 aluminum and 350 bar for steel or ductile iron; the cartridge limit still applies.
- Ask SAROIT to confirm the selected order code and the current installation drawing before manufacture or installation.
The dock leveler manifold guide shows how to document deck and lip movements separately in a circuit enquiry.
Frequently asked questions
How do TPS-08 and TPS-10 sequence valves operate?
Below the preset pressure at port 1, flow at port 1 is blocked and the path from port 2 to port 3 is open. When pressure at port 1 reaches the preset value, the cartridge shifts to open port 1 to port 2.
How does TPS2-10 differ from TPS-10?
TPS2-10 uses pressure at port 1 to control the flow path from port 3 to port 2. Its spring chamber drains at port 2, so port 2 back pressure adds to the setting at a 1:1 ratio. Its catalog operating pressure is 207 bar; TPS-10 is listed at 240 bar.
Is the valve pressure rating the same as the housing material rating?
No. The catalog lists 207 bar for 6061-T6 aluminum bodies and 350 bar for steel or ductile-iron bodies. These body figures do not increase the selected cartridge rating. The complete assembly must meet the limits of the cartridge, body and other components.
What flow rate should I use for selection?
The catalog directs selection to the model-specific pressure and flow curves rather than a single maximum flow number. The published curves use 32 cSt oil at 40 °C. Send the required flow and allowable pressure drop for selection.
What do I need to specify when ordering?
Specify TPS-08, TPS-10 or TPS2-10; the spring-range code; the required pressure setting in bar; and the body port option. Include the circuit diagram, flow, working pressure, downstream back pressure and fluid conditions so the selection can be checked.
Request a Quote for Cartridge Sequence Valves
Send your circuit diagram, required flow, pressure requirements, body porting, quantity and operating conditions. Include any downstream back pressure so SAROIT can review the appropriate valve configuration.
Sequence Valve Model Details
Review SAROIT catalog specifications, spring ranges, hydraulic symbols and drawings on each model page.