SAROIT · Pressure control
SAROIT TADRV2-10 is a cartridge relief valve with a 10-2 cavity and a 250 bar operating-pressure rating. Four spring codes provide different setting ranges, allowing the pressure-control specification to be matched to the circuit.

How TADRV2-10 works
In a relief-valve circuit, inlet pressure opens a discharge path when the selected setting is reached. Use the TADRV2-10 hydraulic symbol and sectional drawing to review the port arrangement, and select a spring code based on the required setting and relief flow.
TADRV2-10 specifications
| Operating pressure | 250 bar |
|---|---|
| Cavity | 10-2 |
| Mounting thread | 7/8-14 UNF |
| Spring code 6 | 3.5–41 bar; preset 20 bar |
| Spring code 12 | 10.5–82 bar; preset 41 bar |
| Spring code 23 | 17.3–158 bar; preset 80 bar |
| Spring code 33 | 17.3–227 bar; preset 113 bar |
| Internal leakage | 5 drops/min maximum at 80% of nominal setting |
| Temperature range | −40°C to +120°C |
Hydraulic symbol and technical drawings
Click an image to view it larger. Use the indicated dimensions and port numbers when discussing the installation with SAROIT.



Ordering options
| Order format | TADRV2-10-[spring code]-[setting pressure]-[body porting] |
|---|---|
| Spring codes | 6, 12, 23 or 33 |
| Setting-pressure field | Blank: listed factory preset; specify the required setting in bar |
| Body porting | Blank: no housing; 4T: SAE 4; 6T: SAE 6; 2G: G 1/4; 3G: G 3/8 |
Selection and installation review
Identify the required pressure setting and the highest expected inlet pressure separately. The highest listed spring range ends at 227 bar; the 250 bar operating rating does not extend that adjustment range. Supply the relief flow, fluid conditions and downstream pressure so SAROIT can check the selection and housing interface.
Review the cartridge cavity drawings and standard valve housings when planning the installation. The assembly must stay within the limits of its selected valve, housing and connections.
Custom production and configuration
SAROIT can review custom production requirements for TADRV2-10 and related hydraulic valves. Send your circuit, installation drawing, connection standard, operating conditions and quantity. The proposed configuration, technical limits and production scope are confirmed during the quotation review.
Questions about this model
What is the range of spring code 12?
The setting range is 10.5–82 bar, with a 41 bar factory preset.
Can the code 33 spring be set to 250 bar?
The listed adjustment range for code 33 is 17.3–227 bar. The 250 bar figure is the operating-pressure rating, not the upper adjustment setting for this spring.
Related hydraulic products
- Pressure control valve collection
- TRV-08 Cartridge Relief Valve
- TPSRV3-10 Pilot-Operated Relief Valve
- Hydraulic cartridge valve range
Request a Quote for TADRV2-10
Send your circuit or drawing, required flow, operating pressure, settings, connection details, quantity and working conditions. Include the model number so SAROIT can review the correct valve configuration.