TMP-08-L Manual Hydraulic Unloading Valve

SAROIT · Manual unloading

SAROIT TMP-08-L is a manual unloading valve with L ordering code in the catalog’s manual-valve section. It is a 08-2 cartridge with a listed 250 bar operating-pressure limit. It is manually actuated; no automatic relief setting is specified on this page.

Request a Quote for TMP-08-L

SAROIT TMP-08-L complete sectional dimension drawing
Sectional dimensions from the SAROIT catalog. Enlarge to inspect labels and confirm the approved drawing before machining.
Read the drawing at full resolution

Scroll within the image to inspect small labels.

SAROIT TMP-08-L complete sectional dimension drawing

How TMP-08-L works

In the unactuated state, port 2 and port 1 are isolated. Pressing the actuator opens communication between ports 2 and 1. Review the load and return path before using manual unloading in a hydraulic circuit.

TMP-08-L specifications

Operating pressure250 bar
Cavity08-2
Internal leakage3 drops/min maximum at 250 bar
Temperature−30°C to +110°C
Listed fluidMineral-based fluid, 7.4–420 cSt
Housing material limits6061-T6 aluminum: 207 bar; steel or ductile iron: 350 bar. Check the assembled pressure limit.

Hydraulic symbol, dimensions and performance data

Click a figure to enlarge it. Review readable dimensions and test conditions against the intended installation.

Ordering choices

Order identificationTMP-08-L with the required body / installation configuration
CavityConfirm the full 08-2 cavity drawing and manifold interface before machining

Selection and installation review

Send the circuit diagram, pressures at both ports, expected unloading flow, mounting access and quantity. Do not interpret the 250 bar operating-pressure rating as an adjustable relief setting.

Review cartridge cavity drawings and standard valve housings. A cavity code alone does not establish interchangeability.

Custom production and configuration

SAROIT can review custom production and configuration of TMP-08-L for the specified circuit and quantity. Technical limits, interfaces and production scope are confirmed during quotation review.

Questions about this model

Is this valve automatically pressure actuated?

The catalog describes manual actuation: the port path opens when the actuator is pushed. It does not give an automatic opening setting.

Can an aluminum housing be used at 250 bar?

The catalog lists 207 bar for 6061-T6 aluminum housing material. Confirm the selected assembly against its lowest-rated part.

Related products

Request a Quote for TMP-08-L

Send the model, circuit or drawing, required flow, pressure and setting conditions, connections, quantity and operating conditions.

Send Your Enquiry