SAROIT · Directional control
SAROIT TPCV-10 is a pilot-operated cartridge check valve with a 3.5:1 pilot ratio, a 10-3 cavity and a 250 bar operating-pressure rating. It provides a free-flow path in one direction and a pilot-controlled release path in the other.

How TPCV-10 works
A pilot-operated check valve adds a control-pressure input to a one-way check function. TPCV-10 allows free flow from port 2 to port 3. Reverse flow from port 3 to port 2 remains blocked until pressure at pilot port 1 opens the valve. Pilot selection must consider the complete circuit and the pressure conditions at all three ports.
TPCV-10 specifications
| Operating pressure | 250 bar |
|---|---|
| Cavity | 10-3 |
| Mounting thread | 7/8-14 UNF-2A |
| Pilot ratio | 3.5:1 |
| Cracking pressure options | 1.7, 3.4 or 6.2 bar |
| Temperature range | −40°C to +120°C |
| Flow selection | Request pressure-drop data for the selected cracking-pressure option |
Hydraulic symbol and technical drawings
Click an image to view it larger. Use the indicated dimensions and port numbers when discussing the installation with SAROIT.



Ordering options
| Valve identification | TPCV-10 |
|---|---|
| Cracking pressure | Specify 1.7, 3.4 or 6.2 bar |
| Body porting | Blank: no housing; 6T: SAE 6; 8T: SAE 8; 2G: G 1/4; 3G: G 3/8 |
Selection and installation review
Send the circuit diagram, load-side pressure, available pilot pressure, return-line pressure and required release flow. Confirm the pilot-pressure requirement under actual operating conditions and review leakage requirements with SAROIT. Use the 10-3 cavity and sectional drawing to check the manifold interface.
Review the cartridge cavity drawings and standard valve housings when planning the installation. The assembly must stay within the limits of its selected valve, housing and connections.
Custom production and configuration
SAROIT can review custom production requirements for TPCV-10 and related hydraulic valves. Send your circuit, installation drawing, connection standard, operating conditions and quantity. The proposed configuration, technical limits and production scope are confirmed during the quotation review.
Questions about this model
Which port controls the reverse-flow release?
Port 1 is the pilot port. Pilot pressure opens the otherwise blocked path from port 3 to port 2.
See the pilot-operated check valve working principle guide for the three operating states.
Is this a continuously metering valve?
The documented function is a pilot-operated check. If your circuit requires controlled lowering or metered release, send the circuit for selection review rather than assuming this check valve provides that function.
Related hydraulic products
- Check valve collection
- TCV-08-P Cartridge Check Valve
- TSLV-08 Cartridge Shuttle Valve
- Hydraulic cartridge valve range
Request a Quote for TPCV-10
Send your circuit or drawing, required flow, operating pressure, settings, connection details, quantity and working conditions. Include the model number so SAROIT can review the correct valve configuration.