TPCV-10 Pilot-Operated Check Valve

SAROIT · Directional control

SAROIT TPCV-10 is a pilot-operated cartridge check valve with a 3.5:1 pilot ratio, a 10-3 cavity and a 250 bar operating-pressure rating. It provides a free-flow path in one direction and a pilot-controlled release path in the other.

Request a Quote for TPCV-10

SAROIT TPCV-10 catalog product image
SAROIT catalog product image.

How TPCV-10 works

A pilot-operated check valve adds a control-pressure input to a one-way check function. TPCV-10 allows free flow from port 2 to port 3. Reverse flow from port 3 to port 2 remains blocked until pressure at pilot port 1 opens the valve. Pilot selection must consider the complete circuit and the pressure conditions at all three ports.

TPCV-10 specifications

Operating pressure250 bar
Cavity10-3
Mounting thread7/8-14 UNF-2A
Pilot ratio3.5:1
Cracking pressure options1.7, 3.4 or 6.2 bar
Temperature range−40°C to +120°C
Flow selectionRequest pressure-drop data for the selected cracking-pressure option

Hydraulic symbol and technical drawings

Click an image to view it larger. Use the indicated dimensions and port numbers when discussing the installation with SAROIT.

Ordering options

Valve identificationTPCV-10
Cracking pressureSpecify 1.7, 3.4 or 6.2 bar
Body portingBlank: no housing; 6T: SAE 6; 8T: SAE 8; 2G: G 1/4; 3G: G 3/8

Selection and installation review

Send the circuit diagram, load-side pressure, available pilot pressure, return-line pressure and required release flow. Confirm the pilot-pressure requirement under actual operating conditions and review leakage requirements with SAROIT. Use the 10-3 cavity and sectional drawing to check the manifold interface.

Review the cartridge cavity drawings and standard valve housings when planning the installation. The assembly must stay within the limits of its selected valve, housing and connections.

Custom production and configuration

SAROIT can review custom production requirements for TPCV-10 and related hydraulic valves. Send your circuit, installation drawing, connection standard, operating conditions and quantity. The proposed configuration, technical limits and production scope are confirmed during the quotation review.

Questions about this model

Which port controls the reverse-flow release?

Port 1 is the pilot port. Pilot pressure opens the otherwise blocked path from port 3 to port 2.

See the pilot-operated check valve working principle guide for the three operating states.

Is this a continuously metering valve?

The documented function is a pilot-operated check. If your circuit requires controlled lowering or metered release, send the circuit for selection review rather than assuming this check valve provides that function.

Related hydraulic products

Request a Quote for TPCV-10

Send your circuit or drawing, required flow, operating pressure, settings, connection details, quantity and working conditions. Include the model number so SAROIT can review the correct valve configuration.

Send Your TPCV-10 Enquiry

Scroll to Top